CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
HOM120
SP-120/240V-20A CB
COMMON TRIP, THERMAL MAGNETIC; 1 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING; SIZE 1 INCH W X 2.98 INCH D X 3.13 INCH H; USED ON HOMELINE[R] LOAD CENTER; HOM MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
IN STOCK
CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
HOMT2020
SP-20-20A CB
1 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; SIZE 1 INCH W X 2.98 INCH D X 3.13 INCH H; APPROVAL UL; USED ON HOMELINE[R] LOAD CENTER; HOMT MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
IN STOCK
CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
HOM250
2P-120/240V-50A CB
COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 50 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; USED ON HOMELINE[R] LOAD CENTER; HOM MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
IN STOCK
CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
HOM230
2P-120/240V-30A CB
COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 30 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING; USED ON HOMELINE[R] LOAD CENTER; HOM MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
IN STOCK
CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
HOM220
2P-120/240V-20A CB
COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING; USED ON HOMELINE[R] LOAD CENTER; HOM MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
IN STOCK
CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
HOM115
SP-120/240V-15A CB
COMMON TRIP, THERMAL MAGNETIC; 1 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 15 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING; SIZE 1 INCH W X 2.98 INCH D X 3.13 INCH H; USED ON HOMELINE[R] LOAD CENTER; HOM MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
IN STOCK
CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
HOM240
2P-120/240V-40A CB
COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 40 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; USED ON HOMELINE[R] LOAD CENTER; HOM MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
IN STOCK
MAGNETEK INC
M60L12DCAR
60W,12VDC MAG LED DIMMABLE XFMR

Show all:  Distribution Equipt - Power Transformers & Conditioners

 More Details
IN STOCK
PLUG-ON CIRCUIT BREAKER
EATON
BR120
SP-120/240V-20A CB
THERMAL MAGNETIC; 1 POLE; 120/240 VAC; 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
IN STOCK
MINIATURE CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
QO120
SP-120/240V-20A CB
THERMAL MAGNETIC; 1 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA), 48 VDC VOLTAGE RATING; 20 AMPERE CURRENT RATING; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA), 5 KILOAMPERE AT 48 VDC; PRESSURE PLATE TERMINAL; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING; SIZE 0.75 INCH W X 2.91 INCH D X 3 INCH H; APPROVAL UL, CSA; USED ON QO LOAD CENTER, NQOD PANELBOARD, OEM INTERIOR/SPEED-D[R] SWITCHBOARD DISTRIBUTION PANEL; QO[T] BRAND; QO MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
IN STOCK
MAGNETEK INC
M40L12DCAR
40W,12VDC,CV DRIVER

Show all:  Distribution Equipt - Power Transformers & Conditioners

 More Details
IN STOCK
CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
HOM260
2P-120/240V-60A CB
COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 60 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; USED ON HOMELINE[R] LOAD CENTER; HOM MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
IN STOCK
CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
HOMT1515
SP-15-15A CB
1 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 15 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; SIZE 1 INCH W X 2.98 INCH D X 3.13 INCH H; APPROVAL UL; USED ON HOMELINE[R] LOAD CENTER; HOMT MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
IN STOCK
DISCONNECT SWITCH
MIDWEST ELEC PROD (POWER OUTLETS)
U035F2
30A ENCL FUS PULLOUT
240 V 1 PHASE; 30 AMPERE; POWER RATING 3 HP; FUSIBLE FUSE; METALLIC ENCLOSURE; WIRE SIZE 14 TO 8 AWG SOLID, 14 TO 3 AWG STRANDED (COPPER, LINE/LOAD), 12 TO 8 AWG SOLID, 12 TO 3 AWG STRANDED (ALUMINUM, LINE/LOAD); SIZE 5 INCH W X 2 1/8 INCH D X 7 NCH H; APPROVAL UL

Show all:  Fusible Disconnect Safety Switches

 Spec Sheet   |   More Details
IN STOCK
CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
HOM2100
2P-120/240V-100A CB
COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 100 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 4 TO 2/0 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; USED ON HOMELINE[R] LOAD CENTER; HOM MODEL

Show all:  Standard Trip Plug-In Circuit Breakers